Testo 330-2LL flue gas analyzer with Bluetooth
Flue Gas Analyzer Testo 330-2 LL with Bluetooth for precise oxygen measurement. Makes combustion control and data management simple and wireless.
Delivery
Order before 2:00 PM and we will ship the same day if the item is in stock.
Contact us
-
330-2 LL is an App-controlled Flue Gas Analyzer from Testo
The Flue Gas Analyzer Testo 330-2 LL is easily operated with an app on your smartphone, meaning faster measurements, paperless reports, and always having measurement data available when needed, in short: Flue Gas measurements have become easier and faster. The instrument operates with Bluetooth technology and is therefore not dependent on the internet. The device is ready for measurements 30 seconds after startup.
The top model in Testo's 300 series of measurement instruments for flue gases
Testo 330-2 LL is very user-friendly with its large illuminated color display, allowing for more clear presentation of measurement results, making interpretation easier and quicker for you, and with the new integrated logging options, measurements can be taken over time to precisely track data development.
330-2 LL is more than just a measurement instrument for flue gases
Testo 330-2 LL is a complete flue gas analyzer that, besides flue gas analysis, can measure draft, fine pressure, unthinned CO, differential pressure, differential temperature, CO, CO2 (calculated), and as a new feature, tightness testing on gas pipe systems (only with additional equipment, see the full range of accessories at the bottom of the page).
Flue Gas Measurement Made Simple and Efficient with 330-2 LL
The measurement instrument automatically stops when the water separator is full, has large memory capable of storing up to 400 measurements at once, and all measurement data can be processed via software, making it easy to provide customers with documentation and report measurement data.
Three different sensors in one measurement instrument
When you purchase the top model within Testo's flue gas analyzers, you get three sensors: one for Oxygen, one for Carbon Dioxide, and one for NOx, with LL in the product name standing for Long Life, as the sensor lifespan is expected to be up to 6 years, and we offer a wide range of sensors for replacement and new installation, available under the Accessories menu.
The list of advantages of Testo 330-2 LL is long:
500,000 measurement points, long battery life, replaceable sensors and smart probes, as well as additional equipment like mobile printers, making Testo's flue gas analyzers the best multi-instrument measurement tools on the market for biogas plants and oil boilers.
Read the blog post about the new industry standard for regular oil boiler service
Testo 330-2 LL Features:
- CO up to 8,000 ppm - with H2 compensation
- Automatic instrument shutdown when water separator is full
- Memory for 400 measurements
- Leak testing on gas pipe systems (accessory) can now be performed without a separate measurement instrument
- Connection of external probes for LEL leak detection and CO in ambient air (accessory)
- CO measurements with automatic dilution (indication between 8,000 and 30,000 ppm)
- Integrated draft and gas zeroing without removing the probe from the chimney
Fixed-price service and calibration subscription with 6-year warranty
Enjoy full security and no unforeseen costs for 6 years with the new Fixed-price service and calibration subscription, which provides a 6-year warranty on handheld device, measurement cells, and wear parts, avoiding unexpected extra charges for service and repairs, and automatically reminding you when it's time for annual calibration.
Testo flue gas app
Start/stop Testo 330 LL
Company data in report form
Sending measurement data via email
Testo item number 0632 3307
Technical Data
Measurement Range
±10000 Pa
Accuracy
±0.3 Pa (0 to 9.99 Pa) plus ±1 digit
±3 % of mv (10 to 10000 Pa) plus ±1 digit
Flue Gas O2 Measurement Range
0 to 21 Vol.%
Accuracy
±0.2 Vol.%
Resolution
0.1 Vol.%
Reaction Time t90
< 20 s
Flue Gas CO (with H2 compensation) Measurement Range
0 to 8000 ppm
Accuracy
±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm)
±10 % of mv (2001 to 8000 ppm)
Resolution
1 ppm
Flue Gas CO low Measurement Range
0 to 500 ppm
Accuracy
±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 500 ppm)
Resolution
0.1 ppm
CO determination (with H2 compensation), automatic dilution Measurement Range
0 to 30000 ppm
Accuracy
±100 ppm (0 to 1000 ppm)
±10 % of mv (1001 to 30000 ppm)
Resolution
1 ppm
Flue Gas NO Measurement Range
0 to 3000 ppm
Accuracy
±5 ppm (0 to 100 ppm)
±5 % of mv (101 to 2000 ppm)
±10 % of mv (2001 to 3000 ppm)
Resolution
1 ppm
Flue Gas NO low Measurement Range
0 to 300 ppm
Accuracy
±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 300 ppm)
Resolution
1 ppm
Flue Gas Nolow Measurement Range
0 to 300 ppm
Accuracy
±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 300 ppm)
Resolution
0.1 ppm
Flue Gas Exhaust Measurement Range
-9.99 to +40 hPa
Accuracy
±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)
±1.5 % of mv (+3.01 to +40.00 hPa)
Resolution
0.01 hPa
Temperature Measurement Range
-40 to +1200 °C
Accuracy
±0.5 °C (0 to +100.0 °C)
±0.5 % of mv (remaining range)
Resolution
0.1 °C (-40 to +999.9 °C)
1 °C (> +1000 °C)
Flue Gas Efficiency, Eta (calculated) Measurement Range
0 to 120 %
Resolution
0.1 %
Flue Gas Stack (calculated) Measurement Range
0 to 99.9 %
Resolution
0.1 %
CO2 Calculation (calculated from O2) Measurement Range
0 to CO2 max (Display range)
Accuracy
±0.2 Vol.%
Resolution
0.1 Vol.%
Reaction Time t90
< 40 s
Speed / Volume Flow Measurement Range
0.15 to 3 m/s
Resolution
0.1 m/s
Pressure Measurement Measurement Range
0 to +300 hPa
Accuracy
±0.5 hPa (0.0 to 50.0 hPa)
±1 % of mv (50.1 to 100.0 hPa)
±1.5 % of mv (Remaining range)
Resolution
0.1 hPa
Flue Gas O2 Measurement Range
0 to 21 Vol.%
Accuracy
±0.2 Vol.%
Resolution
0.1 Vol.%
Reaction Time t90
< 20 s
Flue Gas CO (with H2 compensation) Measurement Range
0 to 8000 ppm
Accuracy
±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm)
±10 % of mv (2001 to 8000 ppm)
Resolution
1 ppm
Flue Gas CO low Measurement Range
0 to 500 ppm
Accuracy
±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 500 ppm)
Resolution
0.1 ppm
CO determination (with H2 compensation), automatic dilution Measurement Range
0 to 30000 ppm
Accuracy
±100 ppm (0 to 1000 ppm)
±10 % of mv (1001 to 30000 ppm)
Resolution
1 ppm
Flue Gas NO Measurement Range
0 to 3000 ppm
Accuracy
±5 ppm (0 to 100 ppm)
±5 % of mv (101 to 2000 ppm)
±10 % of mv (2001 to 3000 ppm)
Resolution
1 ppm
Flue Gas NO low Measurement Range
0 to 300 ppm
Accuracy
±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 300 ppm)
Resolution
1 ppm
Flue Gas Nolow Measurement Range
0 to 300 ppm
Accuracy
±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 300 ppm)
Resolution
0.1 ppm
with CO sensor
Ambient CO Measurement Range
0 to 500 ppm
Accuracy
±5 ppm (0 to 100 ppm)
±5 % of mv (> 100 ppm)
Resolution
1 ppm
Reaction Time
Approx. 35 s
with ambient CO sensor
Gas Leak Measurement for Combustible Gases (via gas leak detection sensor) Measurement Range
0 to 10000 ppm CH4 / C3H8; Display range
Accuracy
Optical signal display (LED) sound signal via buzzer
Reaction Time t90
< 2 s
with gas leak detection sensor
Temperature (via pressure sensor) Measurement Range
-40 to +1200 °C max. (depending on sensor)
Accuracy
±0.5 °C (-40 to 100 °C)
±0.5 % of mv (remaining range) plus sensor accuracy
Resolution
0.1 °C
General Technical Data Dimensions
270 x 90 x 65 mm
Operating Temperature
-5 to +45 °C
Warranty
Instrument: 48 months; Sensors: 48 months; Gas sensors (O2, CO) 48 months; NO sensor 24 months; COlow sensor 24 months; Thermocouple 12 months; Rechargeable battery: 12 months
Display Size
240 x 320 pixels
Display Function
Color display
Power Supply
Rechargeable battery pack 3.7 V / 2.6 Ah; main unit 6 V / 1.2 A
Maximum
500,000 readings
Storage Temperature
-20 to +50 °C
Weight
600 g (without rechargeable battery)
| Datablad | Download | File type | |
|---|---|---|---|
|
|
0632 3307HB.pdf | 1299 KB |
| Brochure | Download | File type | |
|---|---|---|---|
|
|
0632 3307HB.pdf | 1299 KB |