Testo 330-2LL flue gas analyzer with O2
Flue Gas Analyzer Testo 330-2 LL an efficient measuring instrument with its own app. Perfect for optimizing firing systems and improving energy efficiency.
Delivery
Order before 2:00 PM and we will ship the same day if the item is in stock.
Contact us
-
330-2 LL is an App-controlled Flue Gas Analyzer from Testo
The Flue Gas Analyzer Testo 330-2 LL is easily operated with an app on your smartphone, meaning faster measurements, paperless reports, and always having measurement data available when needed, in short: Flue Gas measurements have become easier and quicker. The device operates with Bluetooth technology and is therefore not dependent on the internet. The device is ready for measurements 30 seconds after startup.
The top model in Testo's 300 series of measurement instruments for flue gases
Testo 330-2 LL features a large illuminated color display, making it easier to present measurement results more clearly, simplifying interpretation and speeding up your workflow, and with the new integrated logging capabilities, measurements can be tracked over time for precise development analysis.
330-2 LL is more than just a measurement instrument for flue gases
Testo 330-2 LL is a complete flue gas analyzer that, besides flue gas analysis, can measure draft, fine pressure, unthinned CO, differential pressure, differential temperature, CO, CO2 (calculated), and as a new feature, gas system leak testing (with additional equipment available in the Accessories tab).
Flue Gas Measurement Made Simple and Efficient with 330-2 LL
The measurement device automatically stops when the water separator is full, has large memory capable of storing up to 400 measurements at once, and all measurement data can be processed via software, making it easy to provide documentation to customers and report measurement data.
Read the blog post about the new industry standard for regular oil boiler service
The list of advantages of Testo 330-2 LL is long:
500,000 measurement points, long battery life, replaceable probes and smart probes, as well as additional equipment like mobile printers, making Testo's flue gas analyzers the best multi-instrument on the market for measuring biogas plants and oil boilers.
Testo 330-2 LL Features:
- CO up to 8,000 ppm - with H2 compensation
- Automatic instrument shutdown when water separator is full
- Memory for 400 measurements
- Leak testing of gas systems (accessory) now possible without a separate measurement device
- Connection of external probes for LEL leak detection and CO in ambient air (accessory)
- CO measurements with automatic dilution (indication between 8,000 and 30,000 ppm)
- Integrated draft and zero gas adjustment without removing the probe from the chimney
Fixed-price service and calibration subscription with 6-year warranty
Enjoy full peace of mind and no unforeseen costs for 6 years with the new Fixed-price service and calibration subscription, which provides a 6-year warranty on the handheld device, measurement cells, and consumables, avoiding unexpected extra charges for service and repairs, and automatically reminds you when it's time for annual calibration.
Testo flue gas app
Start/stop Testo 330 LL
Company data in report form
Sending measurement data via email
Testo item number 0632 3307
Technical Data
Differential Pressure - Piezoresistive Measurement Range
±10,000 Pa
Accuracy
±0.3 Pa (0 to 9.99 Pa) plus ±1 digit
±3 % of mv (10 to 10,000 Pa) plus ±1 digit
Flue Gas O2 Measurement Range
0 to 21 Vol.%
Accuracy
±0.2 Vol.%
Resolution
0.1 Vol.%
Reaction Time t90
< 20 s
Flue Gas CO (with H2 compensation) Measurement Range
0 to 8000 ppm
Accuracy
±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm)
±10 % of mv (2001 to 8000 ppm)
Resolution
1 ppm
Reaction Time t90
< 60 s
Flue Gas COlow Measurement Range
0 to 500 ppm
Accuracy
±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 500 ppm)
Resolution
0.1 ppm
Reaction Time t90
< 40 s
Flue Gas Determination of CO (with H2 compensation), automatic dilution Measurement Range
0 to 30,000 ppm
Accuracy
±100 ppm (0 to 1000 ppm)
±10 % of mv (1001 to 30,000 ppm)
Resolution
1 ppm
Flue Gas NO Measurement Range
0 to 3000 ppm
Accuracy
±5 ppm (0 to 100 ppm)
±5 % of mv (101 to 2000 ppm)
±10 % of mv (2001 to 3000 ppm)
Resolution
1 ppm
Reaction Time t90
< 30 s
Flue Gas Nolow Measurement Range
0 to 300 ppm
Accuracy
±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 300 ppm)
Resolution
0.1 ppm
Reaction Time t90
< 30 s
Flue Gas Exhaust Measurement Range
-9.99 to +40 hPa
Accuracy
±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)
±1.5 % of mv (+3.01 to +40.00 hPa)
Resolution
0.01 hPa
Temperature Measurement Range
-40 to +1200 °C
Accuracy
±0.5 °C (0 to +100.0 °C)
±0.5 % of mv (remaining range)
Resolution
0.1 °C (-40 to +999.9 °C)
1 °C (> +1000 °C)
Flue Gas Efficiency, Eta (calculated) Measurement Range
0 to 120 %
Resolution
0.1 %
Exhaust Gas (calculated) Measurement Range
0 to 99.9 %
Resolution
0.1 %
Flue Gas CO2 Calculation (calculated from O2) Measurement Range
0 to CO2 max (display range)
Accuracy
±0.2 Vol.%
Resolution
0.1 Vol.%
Reaction Time t90
< 40 s
Speed / Volumetric Flow Measurement Range
0.15 to 3 m/s
Resolution
0.1 m/s
Pressure Measurement Measurement Range
0 to +300 hPa
Accuracy
±0.5 hPa (0.0 to 50.0 hPa)
±1 % of mv (50.1 to 100.0 hPa)
±1.5 % of mv (remaining range)
Resolution
0.1 hPa
Flue Gas CO (without H2 compensation) Measurement Range
0 to 4000 ppm
Accuracy
±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm)
±10 % of mv (2001 to 4000 ppm)
Resolution
1 ppm
Reaction Time t90
< 60 s
Ambient CO Measurement Range
0 to 500 ppm
Accuracy
±5 ppm (0 to 100 ppm)
±5 % of mv (> 100 ppm)
Resolution
1 ppm
Reaction Time
Approx. 35 s
with CO probe
Ambient CO2 Measurement Range
0 to 1 Vol.%
0 to 10,000 ppm
Accuracy
±50 ppm or ±2 % of mv (0 to 5,000 ppm)
±100 ppm or ±3 % of mv (5,001 to 10,000 ppm)
Reaction Time
Approx. 35 s
with ambient CO2 sensor
Gas detection measurement for combustible gases (via gas detection sensor) Measurement Range
0 to 10,000 ppm CH4 / C3H8; display range
Accuracy
Optical signal display (LED) sound signal via buzzer
Reaction Time t90
< 2 s
with gas detection sensor
Temperature (via fine pressure sensor) Measurement Range
-40 to +1200 °C max. (sensor dependent)
Accuracy
±0.5 °C (-40 to 100 °C)
±0.5 % of mv (remaining range) plus sensor accuracy
Resolution
0.1 °C
General Technical Data Dimensions
270 x 90 x 65 mm
Operating Temperature
-5 to +45 °C
Warranty
Device: 48 months; Sensor: 48 months; Gas sensors (O2, CO) 48 months; No sensor 24 months; COlow 24 months; Thermocouple 12 months; Rechargeable battery: 12 months
Display Size
240 x 320 pixels
Display Function
Color display
Power Supply
Rechargeable battery pack 3.7 V / 2.6 Ah; main unit 6 V / 1.2 A
Maximum
500,000 readings
Storage Temperature
-20 to +50 °C
Weight
600 g (without rechargeable battery)
| Datasheet | Download | File type | |
|---|---|---|---|
|
|
0632 3307H.pdf | 1299 KB |
| Brochure | Download | File type | |
|---|---|---|---|
|
|
0632 3307H.pdf | 5078 KB |